Filter Results By:

Products

Applications

Manufacturers

Showing results: 3346 - 3360 of 3405 items found.

  • Patch Panel Automation Switch

    Echola Systems LLC

    Echola's Optical Patch Panel Automation switch allows test engineers/system developers to dynamically reconfigure testbed connections from remote. It reduces test configuration time as they don't need to make any physical fiber connections for each set of tests, so more testing can be performed with fewer resources. It provides all-optical connectivity with zero latency and can be used with any protocols and speed. Unlike O-E-O (optical to electrical to optical conversion) switches you don't need expensive transceivers for each port. The all-optical connectivity also allows systems under test to be tested without introducing another variable (ie, another conversion layer which could introduce significant latency). The patch panel automation switch allows users to configure, control and monitor the device from remote using any standard internet browser, a command line interface (CLI) via Telnet or SSH and SNMP v2c. The event notifications are supported through Syslog. It can be automated using TCL based scripts.

  • Patchcord

    OPTOKON HMA - OPTOKON a.s.

    The OPTOKON HMA optical modules are designed for connection of the nodes of harsh environmental network by the help of cables with optical fibers. The used „Expanded beam technology“ preserves all advantages of signals transmission through the optical lines in field harsh environmental conditions. Benefiting from expanded beam technology, with a long and proven industry track record, the precision optical alignment system creates immunity from water, mud, dust, oil and other contaminants. The HMA Hermaphroditic coupling eliminates the need for adaptors and male and female mating halves. Hermaphroditic housings allow for rapid deployment, creating low loss Single mode, Multimode and Hybrid daisy chained links in a variety of planforms ranging from simplex fiber to a copper Hybrid. The OPTOKON HMA is ideally suited for environmental extremities where low maintenance and quick repairabilty is necessary, the connectors are uniquely field installable and rapidly field repairable.There are two different types of OPTOKON HMA connection modules:

  • Deep Ultraviolet Spectrophotometer System

    VUVAS-10X - McPherson, Inc.

    A new ultraviolet spectrophotometer system for optical metrology just arrived at NASA Goddard! The VUVAS-10X spectrophotometer works best in the 90 to 160 nanometer wavelength range, also known as deep or vacuum ultraviolet (VUV) region. It uses a windowless hydrogen plasma light source and differential pump section to reach many wavelengths beyond those of conventional deuterium lamps. The source also works with other gases, or gas mixtures, for atomic spectral line emission from about 30 nanometers (double ionized Helium gas) up to the Visible light range. The new spectrophotometer system, McPherson VUVAS-10X, uses a one-meter focal length high-resolution monochromator with the special light source, scintillated detector and Model 121 goniometric sample chamber. The system is ideal for optical transmission, absorbance and specular reflectance at incident angles up to 60 degrees. This McPherson spectrophotometer system will help develop, inspect and qualify optical materials and coatings used for very high altitude and extraterrestrial space flight missions.

  • Lightning Current Generator

    Shanghai Guantu Technology Co., Ltd.

    The lightning wave impulse current generator is an impulse current generator that generates a simulated lightning current waveform . Its working process is as follows: first, the transformer charges the capacitor bank through the silicon pile, when the charging voltage reaches a predetermined value, the spark gap is triggered, and the capacitor is discharged through the total inductance and total resistance of the circuit. When the resistance is greater than or equal to the critical damping value, a unidirectional impulse current wave is generated in the circuit. When the resistance is less than the critical damping value, an oscillating impulse current wave is generated. The magnitude of the impact current amplitude is related to the circuit parameters. When the capacitance value and charging voltage are the same, the smaller the inductance value, the greater the current amplitude. In order to obtain as much current as possible, a pulse capacitor with a small inductance value is usually selected, and the total length of the connecting line should be as short as possible when arranging the main capacitor, so that the total loop inductance value can be reduced as much as possible.

  • pHTestr® 30+ Waterproof Pocket Tester

    OAKTON Instruments

    Waterproof pHTestr 30 is great for outdoor applications such as taking pH measurements in lakes and streams. Designed to float in water, you can even attach a line to the housing for easy retrieval. Valox sensor housing resists most chemicals.The pHTestr 30 has a replaceable sensor for easy maintenance. pHTestr 30 purchased before Oct. 2019 use replacement sensor 35624-38. pHTestr 30 purchased after Oct. 2019 use replacemenr sensor 35634-03. Double-junction electrode sensor handles wastewater and solutions containing sulfides, heavy metals, and TRIS. Electrode sensor offers a clog-resistant Kynar® junction and a recessed, glass pH bulb to protect against breakage.The keypad clicks to confirm operation, and allows access to a variety of functions. Calibrate up to three pH points with the auto-buffer recognition at both USA and NIST standard buffers. Additional features include a automatic temperature compensation (ATC), hold function, auto-off function, self-diagnostic error messages, and a three-segment battery-life indicator.

  • UV Cameras

    Inframet

    Solar blind UV cameras are imaging devices optimized to detect ultraviolet light of wavelengths below about 280nm. Such cameras are insensitive against sunlight due to negligible sensitivity to visible and long wavelength UV light. Solar blind UV cameras are used in a series of applications like corona detection, fire detection, combustion analysis, plasma research, testing UV lamps, etc. However, highly sensitive corona detection is the main mass application and these devices are of crucial importance in electric power industry. These imaging devices enable easy detection of degraded insulators of high voltage transmission lines, distributions and substations. They can see the emission of UV light when discharges occur at defect insulators. From design point of view solar blind UV cameras are actually bispectral imaging systems built by combining true UV camera with typical visible camera. These bispectral imaging system generate output image as overlay of typical visible image with UV image of analyzed UV source.

  • Low Power Programmable AC Source with Transients

    61500 Series - Chroma Systems Solutions, Inc.

    Power:500VA (61501)1500VA (61503)2000VA (61504)4000VA (61505)Voltage range: 0-150V/0-300V/AutoCompact size and weight attributable to advance PWM technologyAC+DC output mode for voltage DC offset simulationProgrammable slew rate setting for changing voltage and frequencyLow output impedance for testing IEC 61000-3-2 (61505)Programmable output impedance for testing IEC 61000-3-3LIST, PULSE, STEP mode function for testing power line disturbance (PLD) simulation capabilityIEC 61000-4-11 voltage dips, short and variation simulationHarmonics, inter-harmonics waveform synthesizer for testing IEC 61000-4-13Programmable voltage, current limitComprehensive measurement capability, including current harmonicsHigh output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates output transientAnalog programmable interface3 units combined to 3-phase power outputEasy-use software for operation and IEC regulation testOptional GPIB and RS-232C interface

  • Optical Delay

    ODL - MesaPhotonics, LLC

    The Peregrine Optical Delay Line (ODL) provides an exceptional combination of precision, speed, and optical stability at a low price. It is ideally suited for pump-probe experiments and autocorrelation measurements (both interferometric and intensity methods). Advanced voice coil technology allows the ODL to be positioned anywhere in its travel range to within 150 nm. That’s 1 fs for a double-pass configuration. The response time is as short as 1 ms. Our 1-cm-travel ODL is interferometrically stable (measured using a 650 nm laser). No backlash, no hysteresis and no drive trains to wear out as with stepper motors. It’s convenient–the ODL can be positioned using digital commands, an analog voltage or a combination of the two. Two 16-bit on-board analog-to-digital converters simplify data collection. Digital inputs and outputs allow master or slave clocking. An executable Windows application is provided to get you up and running in minutes. In addition, DLLs and LabVIEW Vis for integration into your software are also included.

  • Handheld Audio Analyzer

    PAA3X - Phonic Corporation

    The PAA3X is a highly accurate handheld audio analyzer that gives sound engineers a rich array of sound analysis tools. The system features both 61-band and 31-band real time spectrum analysis, RT60 reverb time measurement, SPL and line meter, internal signal generator, EQ setting program, microphone calibration and speaker phase checking abilities. All functions and menus can be accessed through a central jog dial, leaving your other hand free to adjust audio settings. The large color LCD screen has an adjustable brightness to help you see in a dark or well-lit environments alike. The PAA3X also features a "screen capture" function allowing users to save images of the screen to an SD card in BMP format for later reference. The detachable precision microphone can be placed remotely via the included 5-meter extension cable, offering flexible on-site operation management. With all this plus a built-in rechargeable lithium-ion battery, the PAA3X is a must-have multifunctional tool for all serious audio engineers.

  • Colorimeter​​

    Model CA-600​​​ - Teledyne Analytical Instruments

    The​ CA600 is an online sequential sampling analyzer, using colorimetric methods. The analyzer can be configured to most laboratory colorimetric tests in individual processes.The CA600 Analyzers are easy to start up and use, simply connect the sample, waste and reagent lines and then power up the factory calibrated analyzer.​ Wall mount hardware is standard but an optional bench-top stand with reagent holder is also available. Accessing information for customizing an analysis routine is easily accomplished with the simple, user friendly menu structure and touch screen interface.The analyzer has two separated enclosures with two lockable doors. The top enclosure, called the electrical enclosure, includes the main power supply, the controller PCB assembly and the touchscreen interface. The bottom enclosure, called the liquids enclosure, includes all the components involved in the sample and reagent flow, mixing and reaction stages (sampling pump, reagent micro pumps and colorimetric reaction cell). Numerous analysis configurations can be programmed, depending on the accessories and the number of micro-pumps mounted in the liquid enclosure.

  • Digital (1kV up) H.V. Insulation Testers

    7015 IN - Standard Electric Works Co., Ltd

    ● Protection class: IP66 (Lid closed)● Microprocessor controlled.● 2 Lines x 16 characters, large intelligent LCD module.● 30 insulation test voltages : 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 12.5kV, 13kV, 13.5kV, 14kV, 14.5kV, 15kV● AC/DC Voltmeter.● PI (Polarization Index) indication.● DAR (Dielectric Absorption ratio) indication.● Auto-ranging on all insulation ranges.● Current measurement.● Backlight function.● Menu driven.● Visual and audible warning if external voltage is present. (≥30Vac or ≥30Vdc)● Short-circuit current up to 5mA● Auto-hold function to freeze the reading.● Overload protection.● Adjustment for testing time (duration) : 1~30 minutes.● Calendar.● Indication memory for data storage.● Optical USB to RS-232 data transmission.● Auto-off.● 200 measurement results can be saved in the memory and recalled on the display.

  • cRIO-9055, 1.33 GHz Dual-Core CPU, 2 GB DRAM, 4 GB Storage, -40 °C to 70 °C, Artix-7 A100T FPGA, Extended Temperature, 4-Slot CompactRIO Controller

    787879-01 - NI

    1.33 GHz Dual-Core CPU, 2 GB DRAM, 4 GB Storage, -40 °C to 70 °C, Artix-7 A100T FPGA, Extended Temperature, 4-Slot CompactRIO Controller - The cRIO-9055 is a rugged, deployable controller for data acquisition and control applications. It offers Intel Atom dual-core processing, an Artix-7 FPGA, and four slots for C Series modules. It runs the NI Linux Real-Time operating system with access to the I/O through NI-DAQmx drivers or with the LabVIEW FPGA module. The controller provides precise, synchronized timing and deterministic communications over the network using TSN, ideal for distributed measurements and control. This controller offers two Gigabit Ethernet ports, one USB 3.1 host port, one USB 2.0 device port, a trigger line, and a μSD card slot for storing data locally. The registered trademark Linux® is used pursuant to a sublicense from LMI, the exclusive licensee of Linus Torvalds, owner of the mark on a worldwide basis.

  • cRIO-9055, 1.33 GHz Dual-Core CPU, 2 GB DRAM, 4 GB Storage, -40 °C to 70 °C, Artix-7 A100T FPGA, Extended Temperature, 4-Slot CompactRIO Controller

    787043-01 - NI

    1.33 GHz Dual-Core CPU, 2 GB DRAM, 4 GB Storage, -40 °C to 70 °C, Artix-7 A100T FPGA, Extended Temperature, 4-Slot CompactRIO Controller - The cRIO-9055 is a rugged, deployable controller for data acquisition and control applications. It offers Intel Atom dual-core processing, an Artix-7 FPGA, and four slots for C Series modules. It runs the NI Linux Real-Time operating system with access to the I/O through NI-DAQmx drivers or with the LabVIEW FPGA module. The controller provides precise, synchronized timing and deterministic communications over the network using TSN, ideal for distributed measurements and control. This controller offers two Gigabit Ethernet ports, one USB 3.1 host port, one USB 2.0 device port, a trigger line, and a μSD card slot for storing data locally. The registered trademark Linux® is used pursuant to a sublicense from LMI, the exclusive licensee of Linus Torvalds, owner of the mark on a worldwide basis.

  • Battery Analyzer

    KT-97E - KILTER ELECTRONIC CO.,LTD

    ● ImpedanceRange: 6mΩ / 60mΩ / 600m Ω / 6Ω (auto-range)Accuracy: ±1.5% of reading ±3digits Resolution: 0.001mΩ● CapacityRange: 0 ~ 9999Ah Accuracy: ±1.5% of reading ±3digits Resolution: 0.001Ah● DCV Range: 6V / 60V (auto-range) Accuracy: ±0.5% of reading ±3digits Resolution: 0.001V● DCARange: 6A / 60A / 200A (manual) Accuracy: ±1.5% of reading ±3digits Resolution: 0.001A / 0.01A / 0.1A● Temperature Range: -20℃~100℃Accuracy: ±1.0℃ Resolution: 0.1 ℃ ● Set discharge end voltage manually.● Auto alarm when capacity measurement finish .● Data Storage  50 records of impedance and voltage data are available to store into memory .● RS-232 ●  Supplied with lithium rechargeable batteries, very easy to charge with AC power line. Application:● Measure the impedance and capability of rechargeable batteries. which voltage below 60V, ● A perfect tool for identify the batteries used in UPS devices, vehicle,emergency lighting, alarm, sprinkler systems, business security deviceselectro motion ca r etc..

  • Power Quality Analyzer

    PQM-703 - Sonel S.A.

    Power quality analyzer PQM- 703 is a technically advanced product that allows for comprehensive measurements of the quality of electricity , analysis and recording of power network parameters, for frequencies 50/60 Hz in accordance with European standard EN 50160. PQM -703 is another representative of a well, known family of analyzers line PQM- 70x . In relation to the PQM -702 has new functions like recording of transients with max. sampling frequency 10 MHz (rapid changes in voltage) and control signals. Minimal transient capturing time is 650 ns. It is intended for a very wide range of users who need to control the quality of power with a mobile device , which fulfills the requirements of a multi-sheet standard IEC 61000 for class A analyzers. This applies to measurement accuracy, measurement methods, and synchronization of time with a standard signal. The last condition is met with a built-in GPS module with an internal antenna. If the analyzer is installed inside, it is possible to use an additional antenna with a 10m-long wire. If the antenna is situated outside, GPS signal will be attainable without any problems and used for the synchronization of an internal clock.

Get Help